Note: Do not mix and match V6, Volcano, or Cyclops nozzles with the other's heater blocks. Filament will go everywhere and you will be sad.

Using pliers rotate the heater block to loosen the heat break from the heat sink.

Heat up your HotEnd to 285°C. Do not overshoot as you risk damaging your thermistor.