Titan Motor only vibrating back and forth

Hi, I just bought a Titan extruder with the motor for my Anycubic I3 Mega, first, it’s really loud and it will only vibrate back and forth, I followed the firmware tutorial, changed the steps and so on, but when I try to extrude that’s what it does…

Any help appreciated

Answer this question I have this problem too

Is this a good question?

Score 0
Add a comment

2 Answers

Most Helpful Answer

Hi Maxime,

It sounds like the coil pairs are different from the original motor you were using, and the connection point that enters the board try switching the middle two wires with each other.

Was this answer helpful?

Score 1
Add a comment

Thanks that did it! Now I have a terrible oozing problem retraction doesn’t seem to be working

Was this answer helpful?

Score 0

Comments:

Did you change your E step value? I know Titan is different than stock. I used a bondtech and started off with 415. I believe Titans are a higher value. Check to see what they say should be a starting point and then calibrate extrusion from there.